  1. 60 amp breaker feeding a subpanel with breakers totaling 100 amps

    Aug 19, 2019 · The 60 amp breaker feeding this could support 300 amps for 6 seconds based on that. I mention 10 seconds because that is the class I use . The common classes are 5, 10, 20 there are …

  2. What size wire should I use for a 60amp subpanel?

    2 I am installing a 60 amp subpanel in a workshop in my backyard and I will have 2 - 20 amp services with 4-5 outlets on each and 1 - 15 amp service for lighting. The length from the main panel to the …

  3. Can I add a 60 amp breaker to my main service disconnect?

    Jan 27, 2024 · 3 I am looking to add a 60 amp breaker like this one to my main service disconnect so I can install an electric car charger right next to it. My panel for the rest of the house is a lot farther …

  4. electrical - I would like to know if I can run a 60 amp sub panel, off ...

    Mar 12, 2022 · Am I able to run a 60 amp sub panel off a 100 sub panel, while traveling 315'?

  5. What size wire for a 300' run to a 60A sub-panel?

    Sep 17, 2020 · I am going to be running wire underground to my shack about 300' away. I will need a 30amp a 20 amp and a 10 amp at the sub panel at the shack so 60 amps total. I assume I am going …

  6. What size wire for a 60 AMP panel 400 feet away?

    Mar 10, 2021 · We are putting a sign and several lights in our parking lot and need a 60 amp panel to be located 400 feet from the breaker box. Allowing for the voltage drop, what size wire do we need to run?

  7. Can I add a 60 AMP EV circuit to an existing 200 AMP service?

    Nov 27, 2023 · My existing service is 200 AMPs. Everything has been working fine. I now want to add an additional 60 AMP EV charging station (hardwired). Is this not feasible? Would I need a much larger …

  8. electrical - 60 amp sub panel to external garage from house - overhead ...

    Oct 16, 2021 · First time running overhead drop from home to unattached garage, main panel more than able to support service... need 60' to 70' run. I am familiar with NEC but not a professional.

  9. Is 12 AWG ground wire adequate for a 60 Amp water heater circuit?

    The black and red go to a 2 pole 60 amp breaker with the yellow/green going to ground/common on a very old Cutler-Hammer breaker box. I went to the local box store and they didn't have the 3 6 AWG …

  10. Conduit Size for Sub-Panel run? - Home Improvement Stack Exchange

    Apr 18, 2016 · It is 60 feet from main panel through crawl space. It is another 60 feet underground through the yard, and 10 feet inside the garage to the sub-panel. I'm know the length of the run will …